Documentation

Phoscon Smartphone App

The Phoscon Smartphone App is a powerful tool to configure and control small and larger smart light installations. Specializing in the popular wireless standard Zigbee, the Phoscon App supports a steadily growing number of lights, sensors and switches from various well-known manufacturers. The possibilities and functions of the Phoscon Smartphone App are constantly being expanded and improved.

The download is available in the Google Play Store and Apple App Store.

Google Playstore Logo

Apple App Store Logo

The Phoscon Smartphone App can be used without restrictions with the dresden elektronik products RaspBee, RaspBee II, Phoscon Gateway as well as ConBee and ConBee II.

Gettings started

Open the Phoscon App on the smartphone. The gateway is displayed with the name Phoscon-GW and its current IP address.

If not, the search for the gateway can be started via. Furthermore the gateway can be linked to the app by entering the IP address and the Port.

Gateway list

Select the gateway and specify a name and login password.

Note: The IP address is typically assigned by the Ethernet or WIFI router. Use Port 80 if no specific port is defined.

Set login password

The login password secures the access of the gateway in the local network. It can be changed later within the gateway settings.

Set login password

Create first group

For the next steps, it is necessary to create a first group to which the formerly connected lights will be added.

Create first group

Individual lights can be grouped and controlled together. For example, a group can represent an entire room such as the living room or kitchen, or just parts of it such as the dining area. Each light can be assigned to up to eight groups.

Daytime

Menu > Daytime

The prerequisite for creating an automation is the setting of the four specified times of day:

The times of day can follow the daily course of the sun or can be set permanently. The course of the sun, i.e. sunrise and sunset, are determined via the system time in the gateway.

If this cannot be done automatically, the system time must be set manually in the gateway settings.

Daytime

Define daytime

Each time of day can be edited by individually. In order to follow the changing position of the sun throughout the year, each beginning and end of a time of day can be defined as moving.

To do this, the point on the slider must be pressed.

time wheel

Lights

Adding lights to a group

Mainpage > Groups > Edit > Manage lights

In order to control a light, it must be assigned to a group. Only lights belonging to a group are displayed on the main page.

Adding lights to a group

Lights can be assigned to or removed from the selected group. Lights are assigned to the group via . With lights can be removed from the group.

Adding lights to a group 2

If a light is selected, it will start flashing and can be identified. Furthermore it can be renamed in the appearing dialog.

Add more lights

Add more lights

Using lights that are in the factory state can be connected to the gateway in the next 3 minutes. These appear next to the already available lights with a green background. the learning of the first lights is started.

The light search duration can be adjusted in the Gateway Settings.

If no lights are found, this can have different causes. After a failed light search, a dialog appears that provides illustrated instructions for resetting lights to factory new settings. Further information on problems with connecting can be found in the Troubleshooting section.

Control lights

Mainpage > Groups

On Groups on the main page, the lights of a group can be controlled. Either the whole group or the lights can be adjusted individually.

Control lights

The symbols for groups and lights indicate their current state. They are also used to switch them on and off.

Control lights 2

The color and brightness can be changed. Depending on the lamp type, different control options are displayed. These are automatically recognized by the gateway.

Control lights 3

Scenes

Lighting moods can be saved in scenes and called up via the Phoscon App, a timer or a switch. Scenes can be customized for different situations, such as watching TV or reading.

Create scenes

Mainpage > Groups > Edit > Scenes editor

The scenes are configured using the Scene editor.

Create scene

Light state can be set in the same way as on the main page for the whole group or individually. Once the desired scene has been created, it can be saved and recalled at any time from the main page, a schedule or by a switch.

Edit scenes

Mainpage > Groups > Edit > Scenes editor > Setting

The individual settings of a scene can be adjusted at any time and saved again. Please note that the lights used in the scene must be switched on to apply the changes.

Scene settings

Within Settings you can define a Fading time. This ensures a natural and smooth transition when the scene is recalled.

Recall scenes

Mainpage > Groups > Scenes

Scenes of a group appear on the main page under Scenes and can easily be recalled from there by selecting them.

Szenen aufrufen

Changes to a scene can be made via the Scene editor.

Automations

The automation of devices allows sensor- and daytime-controlled events to be triggered.

When using the previous sensor control, it is strongly recommended to completely delete the rules created before new rules are created in the automation. The use of identical sensors and devices in sensor control and automation can lead to incorrect rules and behavior.

Add automatiion

Main page > Groups > Edit > Automations

One or more automations can be created by for each group.

Automation overview

Edit automation

The automation created always consists of two actions that take place:

The follow-up time begins after the automation has been triggered and can be set using a slider. Values between 10 seconds and 60 minutes are possible.

Create automation

Define event

Events can be assigned to each action:

Select trigger

Automation can be triggered by one or more devices. All sensors trained in the system are available as selectable triggers.

Trigger overview

The trigger can be selected individually.

Triggers that are grayed out are not available for selection because, for example, they are no longer accessible.

Select trigger

A trigger can have one or more events assigned to it that trigger automation:

Some examples of events can be:

Edit device

The current sensor values of the trigger are displayed in a continuous diagram. Depending on the refresh rate of the selected trigger, it may take several minutes for a change to become visible.

Sensor values

Define daily schedule

Automation can be activated or deactivated for any of the four available times of day.

Define daily schedule

Manage lights

This page provides an overview of all lights which are connected to the gateway.

Menu > Devices > Lights

Lights overview

On this page, all connected lights and sockets are listed with name and manufacturer. Here you can see the current status of each individual device. It shows whether the light is currently switched on, switched off or possibly not accessible (for example if it is not connected to the power supply).

Lights overview

*By selecting the light symbol, the light will flash for 30 seconds.

Connect new lights

Via further lights can be connected to the gateway.

Especially for larger installations, it is recommended during light search to supply the lights with power one after the other and to wait until the light is shown in the list. If problems occur during the search process please refer to section Troubleshooting.

Light details

By selecting a certain light via its name in the list, you get to its detailed view.

Light details

Rename, delete

When a light is deleted, it is reset to factory settings and removed from the gateway. All scenes and group memberships of the light will be lost.

Manage plugs

Menu > Devices > Plugs

This page provides an overview of all plugs which are connected to the gateway.

Plugs overview

Under Plugs all plugs are listed with their names.

Plugs overview

Plugs details

By selecting a certain plug via its name in the list, you get to its detail view.

Plugs details

Rename, delete

After deleting a plug it must be reset to factory settings before it can be connected again to a gateway. Please refer to the manufacturer’s operating instructions.

Add a new plug

To add a new plug, select . A dialog opens with a selection of devices. Then follow the steps of the instructions or refer to the manufacturer’s operating instructions.

Motion Sensor

Manage switches

Menu > Devices > Switches

This page provides an overview of all switches which are connected to the gateway.

Switch overview

Under Switches all wall switches and remote controls are listed with name and manufacturer. Here you can see the status of each individual device, for example if it is currently not available (if the battery is empty).

Switches overview

Switch details

Selecting a switch by selecting the name in the list takes you to its detail page.

Switch details

Rename, delete

After deleting a switch it must be reset to factory settings before it can be connected again to a gateway. Please refer to the manufacturer’s operating instructions.

Add a new switch

Menu > Devices > Switches

To add a new switch, select . A dialog opens with a selection of devices. Follow the steps of the instructions or refer to the operating instructions of the manufacturer.

DE Scene Switch

Switch editor

Mainpage > Groups > Edit > Switch editor

Switches can control any number of light groups, several switches can be assigned to each group.

Switch selection

First, a switch must be linked to the light group to be controlled.

Select switch

Overview

All assigned buttons are displayed for each configured switch.

Overview

Depending on the function of the button assignment, it can be modified. For example, another scene can be selected for a scene button. If a button is to be assigned a completely different function, the old assignment must first be deleted and then the new assignment can be created.

Button assignement

Manage sensors

Menu > Devices > Sensors

This page provides an overview of all sensors which are connected to the gateway.

Sensor overview

Under Sensors all sensors are listed with their names and currently measured values, such as movement, brightness, temperature, humidity, air pressure etc..

Sensors overview

The virtual daylight sensor is provided by the gateway and calculates sunrise, sunset and twilight phases using the position and time of the current location. This information can be used in automations.

Sensor details

By selecting a certain sensor via its name in the list, you get to its detail view.

Sensor details

Rename, delete

After deleting a sensor it must be reset to factory settings before it can be connected again to a gateway. Please refer to the manufacturer’s operating instructions.

Add a new sensor

To add a new sensor, select . A dialog opens with a selection of devices. Then follow the steps of the instructions or refer to the manufacturer’s operating instructions.

Motion Sensor

Manage blinds

Menu > Devices > Blinds

This page provides an overview of all blinds which are connected to the gateway.

Blinds overview

Under Blinds all connected blinds are listed with their names.

Blinds overview

Blinds details

By selecting a certain blinds via its name in the list, you get to its detail view.

Blinds details

Rename, delete

After deleting a blinds it must be reset to factory settings before it can be connected again to a gateway. Please refer to the manufacturer’s operating instructions.

Add a new blinds

To add a new blinds, select . A dialog opens with a selection of devices. Then follow the steps of the instructions or refer to the manufacturer’s operating instructions.

Schedules

Mainpage > Groups > Edit > Schedules

Schedules allows to perform an action for a group at a specific time, such as activating a scene or turning off the group. A distinction is made between the two variants Alarm and Timer.

Schedules

Alarm

An alarm performs the desired action regularly at the specified time on the selected weekdays.

Alarm settings

If lights have to switched on, a scene must be created in which each light in the group defines the desired state such as on/off, dimming value and color.

Since scenes can be configured with a long fading time of several minutes, you can select whether the scene is to start or finish at the specified time with Fading begins/ends.

Timer

A timer executes an action only once after the selected time has elapsed.

Timer settings

The actions Turn group off and Call a scene, as well as settings of the fading time of scenes are configured identically as for an Alarm.

Settings

Gateway

Menu > Settings > Gateway

The Gateway settings are divided into three subcategories: General, Advanced and Power.

General

Information on the current version and firmware can be found under General.

The gateway should only be reset in exceptional cases, as all settings for devices, groups, scenes and automations are deleted.

General Settings

With the you can save all settings such as devices configuration, their names, groups, scenes and sensor controls in a file and restore them later if necessary.

It is recommended to create a backup before each update and after each completed configuration.

Advanced

With the time of the Phoscon app can be set. This usually happens automatically. Setting the correct time is necessary for time-based rules and functions.

Advanced Settings 1

With the gateway can be connected to other apps and home automation devices like Amazon Echo. If activated, the gateway must be connected within 60 seconds in the respective app. If necessary the gateway IP address must be entered.

To connect Amazon Alexa please say only Alexa: Discover devices.

With potential problems with overlapping WiFi channels can be solved. This option should only be used in an emergency, all lights must be switched on.

Advanced Settings 2

The duration of the light search can be increased to facilitate commissioning, especially in larger installations.

Advanced Settings 3

Restart, power-off

The gateway can be restarted or powered-off under Power.

Power settings

WiFi

Menu > Settings > WiFi

Accesspoint

The integrated WiFi accesspoint (hotspot) allows the autonomous operation of the gateway. Mobile devices such as tablets and mobile phones can be connected to the access point.

Note To change the configuration, the gateway must be connected to a WiFi router via LAN cable.

After connecting to the accesspoint, the Phoscon Smartphone App can be connected with the gateway.

The gateway can be operated as an access point or client.

Accesspoint settings

The WiFi name (SSID) and the password can be configured for the accesspoint. For the Phoscon Gateway the preconfigured individual WiFi password is located on the back of the gateway.

In client mode the gateway can be connected to an existing WiFi network.

Client mode settings

Device integration

Mainpage > Device integrations

This function can be used to integrate devices that are not yet supported. The device description is done via so-called Device Description Files, DDF for short.

The technical documentation about DDFs is here available: https://dresden-elektronik.github.io/deconz-dev-doc/modules/ddf/

Where do I get DDFs?

DDFs can currently be obtained via the external community project deconz-toolbox.

Load DDF

A DDF can be selected via and then loaded via .

Device integration

Troubleshooting

Light cannot be connected

If a light cannot be connected, it may have different causes. Resetting the light to factory settings should help.

Factory settings via reset sequence

Menu > Help > Reset lights

In the Help menu specific manufacturer instructions can be found for IKEA Trådfri, OSRAM Lightify/Smart+ and dresden elektronik FLS products describing how to reset to factory settings via an on/off sequence.

Factory settings via remote control

Menu > Help > Reset lights

Alternatively to the reset sequence and for Philips Hue lights, the reset to factory settings can be done with a Philips Hue dimmer, GIRA or JUNG remote control. The instructions can also be found in the Help menu.

IKEA Trådfri and OSRAM Lightify/Smart+ lights

If the lights cannot be taught-in despite factory settings, please make sure that the lights have to be switched off for a short time (Powercycle) while the light search is running.